Technical specification
|
|||
Sensing input
|
|||
voltage
|
190 ~ 264 VAC, 1 phase 2 wire
|
||
frequency
|
50/60Hz Single Phase
|
||
output
|
|||
voltage
|
Max. 90 VDC at 207 VAC
|
||
Current
|
Continuous 4A, Intermittent 10 A for 10 sec
|
||
resistance
|
15 ohms min
|
||
regulation
|
+/- 1.0% (with 4% engine governing)
|
||
Thermal drift
|
0.04% per °C change in AVR ambient
|
||
Under frequency protection
|
|||
Set point
|
95% Hz
|
||
Unit power dissipation
|
12 watts maximum
|
||
ANALOGUE INPUT
|
|||
Maximum input
|
+/- 5V dc
|
||
Sensitivity
|
1v for 5% Generator Volts (adjustable)
|
||
Input resistance
|
1k ohm
|
||
QUADRATURE DROOP INPUT
|
|
||
Max. sensitivity
|
0.07 A for 5% droop 0PF
|
||
Max. input
|
0.33 A
|